![]() In retreatment procedures, gutta percha solvents dissolve the existing root canal filling which makes the process of removal smoother. Gates Glidden drills are used to enlarge the coronal and middle portions of the canal through bulk removal of the tooth structure. Pulp devitalization materials help render the infected pulp, non vital facilitating extirpation.īarbed broaches help extirpate the degenerated pulp tissue. Canal probes can be used in locating the root canal orifices. The first step in endodontic treatment involves the access cavity preparation which ideally results in gaining a straight line access.Įndodontic burs such as the round bur with collar, non end cutting bur aid in preparing the access cavity and deroofing the pulp chamber. Materials used in endodontic therapy may be categorized according to their usage in the phases of treatment as: What are the dental endodontic material categories? The cleansed and shaped root canal is then filled with an inert substance such as gutta percha along with root canal sealants. Root canal irrigants and intracanal medicaments further reinforce this process. What does endodontic treatment comprise?Įndodontic treatment involves removal of the infected or degenerated pulp tissue followed by biomechanical preparation of the root canal which results in eradication of the infective agents that caused pulpal degeneration. Pulp devitalization materials, Endodontic files, root canal irrigants, obturation materials and root canal filling materials aid the dental professional in delivering quality endodontic treatment. I would definitely recommend X-Smart Endodontic Rotary Motor (Dentsply Sirona) as a must have for your clinic.Endodontic materials are used to clean, shape and fill the root canal system of teeth in which the pulp tissue has been destroyed. You might hear stray incidents of battery problem but it’s performance can hardly be questioned. The handpiece is wired to a tabletop control and display unit, hence it is bulky when compared to other wireless endomotors available today but it’s performance and reliability should be enough of a reason to purchase this as your primary unit. As X-Smart gives you a reliable performance, one should get it just for the peace of mind. Most of the clinics at least initially have a single endomotor. With use over the years, the battery charge has deteriorated but it has never caused me other problems. I have been using X-Smart for the past 10 years. Review of X-Smart Endodontic Rotary Motor (Dentsply Sirona) The battery should be changed if required. The rechargeable battery can be recharged between 300-500 times.If battery falls below 30%, the ‘auto reverse’ feature may not activate. Always try and keep the battery above 30% (single bar).If the file binds in the canal, the rotation of file stops & reverses to prevent binding and fracture of instrument in the canal. You can change the contra-angled head position for your ease of use.Gear ratio can be 1:1, 4:1, 10:1, 16:1, 20:1 depending on the handpiece in use.Torque can be adjusted between 0.6 – 5.2 N-cm using a 16:1 handpiece.Speed can be adjusted between 120 – 800 rpm.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |